diff options
author | Tommie Gannert <tommie@gannert.se> | 2016-08-01 15:25:13 +0100 |
---|---|---|
committer | Tommie Gannert <tommie@gannert.se> | 2016-08-14 20:44:54 +0100 |
commit | d74bc90bfe8ac11ba3d6ac5326d95dedd10c39c3 (patch) | |
tree | 691abcaeaafcea5f5cd1ca553ec35dde59e36123 /src/print_battery_info.c | |
parent | 9970af67e59dfbc758f6158a187c56fa4f3b557a (diff) |
Move full_design and full_last into struct battery_info.
This is in preparation for moving the ratio computation code out of
slurp_battery_info to support aggregating multiple batteries.
Diffstat (limited to 'src/print_battery_info.c')
-rw-r--r-- | src/print_battery_info.c | 78 |
1 files changed, 34 insertions, 44 deletions
diff --git a/src/print_battery_info.c b/src/print_battery_info.c index f131601..d92d9db 100644 --- a/src/print_battery_info.c +++ b/src/print_battery_info.c @@ -29,6 +29,10 @@ #endif struct battery_info { + int full_design; + int full_last; + int remaining; + int present_rate; int seconds_remaining; float percentage_remaining; @@ -58,9 +62,7 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen char buf[1024]; const char *walk, *last; bool watt_as_unit = false; - int full_design = -1, - remaining = -1, - voltage = -1; + int voltage = -1; char batpath[512]; sprintf(batpath, path, number); INSTANCE(batpath); @@ -81,10 +83,10 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_NOW")) { watt_as_unit = true; - remaining = atoi(walk + 1); + batt_info->remaining = atoi(walk + 1); } else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_NOW")) { watt_as_unit = false; - remaining = atoi(walk + 1); + batt_info->remaining = atoi(walk + 1); } else if (BEGINS_WITH(last, "POWER_SUPPLY_CURRENT_NOW")) batt_info->present_rate = abs(atoi(walk + 1)); else if (BEGINS_WITH(last, "POWER_SUPPLY_VOLTAGE_NOW")) @@ -103,41 +105,32 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen batt_info->status = CS_DISCHARGING; else if (BEGINS_WITH(last, "POWER_SUPPLY_STATUS=")) batt_info->status = CS_UNKNOWN; - else { - /* The only thing left is the full capacity */ - if (last_full_capacity) { - if (!BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL") && - !BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL")) - continue; - } else { - if (!BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN") && - !BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN")) - continue; - } - - full_design = atoi(walk + 1); - } + else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN") || + BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN")) + batt_info->full_design = atoi(walk + 1); + else if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL") || + BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL")) + batt_info->full_last = atoi(walk + 1); } /* the difference between POWER_SUPPLY_ENERGY_NOW and * POWER_SUPPLY_CHARGE_NOW is the unit of measurement. The energy is * given in mWh, the charge in mAh. So calculate every value given in * ampere to watt */ - if (!watt_as_unit) { + if (!watt_as_unit && voltage != -1) { batt_info->present_rate = (((float)voltage / 1000.0) * ((float)batt_info->present_rate / 1000.0)); - - if (voltage != -1) { - remaining = (((float)voltage / 1000.0) * ((float)remaining / 1000.0)); - full_design = (((float)voltage / 1000.0) * ((float)full_design / 1000.0)); - } + batt_info->remaining = (((float)voltage / 1000.0) * ((float)batt_info->remaining / 1000.0)); + batt_info->full_design = (((float)voltage / 1000.0) * ((float)batt_info->full_design / 1000.0)); } - if ((full_design == -1) || (remaining == -1)) { + int full = (last_full_capacity ? batt_info->full_last : batt_info->full_design); + + if ((full == -1) || (batt_info->remaining == -1)) { OUTPUT_FULL_TEXT(format_down); return false; } - batt_info->percentage_remaining = (((float)remaining / (float)full_design) * 100); + batt_info->percentage_remaining = (((float)batt_info->remaining / (float)full) * 100); /* Some batteries report POWER_SUPPLY_CHARGE_NOW=<full_design> when fully * charged, even though that’s plainly wrong. For people who chose to see * the percentage calculated based on the last full capacity, we clamp the @@ -148,7 +141,7 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen } if (batt_info->present_rate > 0 && batt_info->status != CS_FULL) { - batt_info->seconds_remaining = seconds_remaining_from_rate(batt_info->status, full_design, remaining, batt_info->present_rate); + batt_info->seconds_remaining = seconds_remaining_from_rate(batt_info->status, full, batt_info->remaining, batt_info->present_rate); } #elif defined(__FreeBSD__) || defined(__FreeBSD_kernel__) || defined(__DragonFly__) int state; @@ -229,10 +222,8 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen * Using envsys(4) via sysmon(4). */ bool watt_as_unit = false; - int full_design = -1, - remaining = -1, - voltage = -1; - int fd, rval, last_full_cap; + int voltage = -1; + int fd, rval; bool is_found = false; char *sensor_desc; bool is_full = false; @@ -313,10 +304,10 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen obj4 = prop_dictionary_get(obj2, "max-value"); obj5 = prop_dictionary_get(obj2, "type"); - remaining = prop_number_integer_value(obj3); - full_design = prop_number_integer_value(obj4); + batt_info->remaining = prop_number_integer_value(obj3); + batt_info->full_design = prop_number_integer_value(obj4); - if (remaining == full_design) + if (batt_info->remaining == batt_info->full_design) is_full = true; if (strcmp("Ampere hour", prop_string_cstring_nocopy(obj5)) == 0) @@ -331,7 +322,7 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen batt_info->present_rate = prop_number_integer_value(obj3); } else if (strcmp("last full cap", prop_string_cstring_nocopy(obj3)) == 0) { obj3 = prop_dictionary_get(obj2, "cur-value"); - last_full_cap = prop_number_integer_value(obj3); + batt_info->full_last = prop_number_integer_value(obj3); } else if (strcmp("voltage", prop_string_cstring_nocopy(obj3)) == 0) { obj3 = prop_dictionary_get(obj2, "cur-value"); voltage = prop_number_integer_value(obj3); @@ -349,17 +340,16 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen return false; } - if (last_full_capacity) - full_design = last_full_cap; - - if (!watt_as_unit) { + if (!watt_as_unit && voltage != -1) { batt_info->present_rate = (((float)voltage / 1000.0) * ((float)batt_info->present_rate / 1000.0)); - remaining = (((float)voltage / 1000.0) * ((float)remaining / 1000.0)); - full_design = (((float)voltage / 1000.0) * ((float)full_design / 1000.0)); + batt_info->remaining = (((float)voltage / 1000.0) * ((float)batt_info->remaining / 1000.0)); + batt_info->full_design = (((float)voltage / 1000.0) * ((float)batt_info->full_design / 1000.0)); } + int full = (last_full_capacity ? batt_info->full_last : batt_info->full_design); + batt_info->percentage_remaining = - (((float)remaining / (float)full_design) * 100); + (((float)batt_info->remaining / (float)full) * 100); if (is_full) batt_info->status = CS_FULL; @@ -368,7 +358,7 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen * The envsys(4) ACPI routines do not appear to provide a 'time * remaining' figure, so we must deduce it. */ - batt_info->seconds_remaining = seconds_remaining_from_rate(batt_info->status, full_design, remaining, batt_info->present_rate); + batt_info->seconds_remaining = seconds_remaining_from_rate(batt_info->status, full, batt_info->remaining, batt_info->present_rate); #endif return true; |