summaryrefslogtreecommitdiff
path: root/src
diff options
context:
space:
mode:
authorTommie Gannert <tommie@gannert.se>2016-08-16 09:18:05 +0100
committerTommie Gannert <tommie@gannert.se>2016-08-22 21:18:31 +0100
commitac8998ef03374abca56da9929812c6fcba936031 (patch)
tree04a7250ee127813fca75e4b42e38bdffe61bc3f5 /src
parent15de209cbaee6827f061e8d2788c9db232012c6b (diff)
Match trailing equal sign in slurp_battery_info.
Should make it more resilient to future ambiguities in uevent.
Diffstat (limited to 'src')
-rw-r--r--src/print_battery_info.c18
1 files changed, 9 insertions, 9 deletions
diff --git a/src/print_battery_info.c b/src/print_battery_info.c
index c20e87e..27473a2 100644
--- a/src/print_battery_info.c
+++ b/src/print_battery_info.c
@@ -65,21 +65,21 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen
if (*walk != '=')
continue;
- if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_NOW")) {
+ if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_NOW=")) {
watt_as_unit = true;
batt_info->remaining = atoi(walk + 1);
- } else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_NOW")) {
+ } else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_NOW=")) {
watt_as_unit = false;
batt_info->remaining = atoi(walk + 1);
- } else if (BEGINS_WITH(last, "POWER_SUPPLY_CURRENT_NOW"))
+ } else if (BEGINS_WITH(last, "POWER_SUPPLY_CURRENT_NOW="))
batt_info->present_rate = abs(atoi(walk + 1));
- else if (BEGINS_WITH(last, "POWER_SUPPLY_VOLTAGE_NOW"))
+ else if (BEGINS_WITH(last, "POWER_SUPPLY_VOLTAGE_NOW="))
voltage = abs(atoi(walk + 1));
/* on some systems POWER_SUPPLY_POWER_NOW does not exist, but actually
* it is the same as POWER_SUPPLY_CURRENT_NOW but with μWh as
* unit instead of μAh. We will calculate it as we need it
* later. */
- else if (BEGINS_WITH(last, "POWER_SUPPLY_POWER_NOW"))
+ else if (BEGINS_WITH(last, "POWER_SUPPLY_POWER_NOW="))
batt_info->present_rate = abs(atoi(walk + 1));
else if (BEGINS_WITH(last, "POWER_SUPPLY_STATUS=Charging"))
batt_info->status = CS_CHARGING;
@@ -89,11 +89,11 @@ static bool slurp_battery_info(struct battery_info *batt_info, yajl_gen json_gen
batt_info->status = CS_DISCHARGING;
else if (BEGINS_WITH(last, "POWER_SUPPLY_STATUS="))
batt_info->status = CS_UNKNOWN;
- else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN") ||
- BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN"))
+ else if (BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL_DESIGN=") ||
+ BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL_DESIGN="))
batt_info->full_design = atoi(walk + 1);
- else if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL") ||
- BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL"))
+ else if (BEGINS_WITH(last, "POWER_SUPPLY_ENERGY_FULL=") ||
+ BEGINS_WITH(last, "POWER_SUPPLY_CHARGE_FULL="))
batt_info->full_last = atoi(walk + 1);
}