summaryrefslogtreecommitdiff
path: root/src/print_battery_info.c
AgeCommit message (Collapse)Author
2018-01-28Treat zero battery capacity as "not available" (#259)johcgt
`print_battery_info` computes `batt_info.percentage_remaining` by dividing batt_info.remaining by `full`. If `full` is `0` then the battery remaining will be reported as "inf". Before this, it tries to set `full` to either the design capacity or to the last known good charge. It determines if these values are available by checking whether their fields in `batt_info` are non-negative. As it initialized `batt_info` with values of `-1`, a non-negative value implies that something has provided a value. `slurp_all_batteries` and `add_battery_info` however initialize these fields to zero, so if these functions are called then `batt_info.full_design` will always be used. This means that on systems that don't provide a value for design capacity the percentage remaining will be reported as "inf", unless the user has set `last_full_capacity` to `true` in their `i3status.conf`. This patch changes `print_battery_info` to expect values for the battery capacity to be strictly greater than zero. This seems reasonable as a battery with a capacity of zero isn't useful. An alternative solution would be to change `slurp_all_batteries` and `add_battery_info` to initialize `batt_info` with `-1`, as `print_battery_info` does. This is less appealing as `add_battery_info` is accumulating the values, so using `-1` would introduce off-by-one errors without additional code to avoid them.
2017-08-24Be more cautious about handling invalid battery measurements.kousu
2017-08-19Use local timezone for battery %emptytime (#236)Emeric Planet
2017-04-13Add battery capacity parsing (#216)Emeric Planet
The Linux power supply class defines three entries to provide battery status. One of them wasn't used: POWER_SUPPLY_CAPACITY. https://www.kernel.org/doc/Documentation/power/power_supply_class.txt
2017-02-07Suppress printing :00 seconds of remaining battery lifetime, as apm(4)'sJasper Lievisse Adriaanse
estimate only has a granularity of minutes. From tb@openbsd.org
2016-10-23Detect batteries using glob (#163)Stu Zhao
2016-08-28Implement aggregates for batteries.Tommie Gannert
Using title number all, this enables aggregates. Note that FreeBSD and OpenBSD previously only reported aggregates, so this is bringing Linux and NetBSD that functionality. Changes the default battery reporting to the aggregate since most users probably don't care about individual batteries. For single-battery systems there should be no change. Fixes one obvious memory leak in NetBSD.
2016-08-22Match trailing equal sign in slurp_battery_info.Tommie Gannert
Should make it more resilient to future ambiguities in uevent.
2016-08-21Added missing ampere to watt conversion for last full capacity. (#158)tnnn
Signed-off-by: Tomasz Nitecki <tnnn@tnnn.pl>
2016-08-14Move time and ratio computations out of slurp_battery_info. (#151)tommie
This allows OSes that support reporting multiple batteries to simply sum into full_design,full_last,remaining and let print_battery_info make computations.
2016-08-14Move full_design and full_last into struct battery_info.Tommie Gannert
This is in preparation for moving the ratio computation code out of slurp_battery_info to support aggregating multiple batteries.
2016-08-14Also capture charge rate in NetBSD.Tommie Gannert
For time estimates when charging.
2016-08-14Fix warnings about using a char array index on NetBSD.Tommie Gannert
The isspace macro is just a table lookup.
2016-08-14Simplify string comparisons in slurp_battery_info for NetBSD.Tommie Gannert
Doing strlen(a) == strlen(b) && strncmp(a, b, N) seems to have no benefits compared to just strcmp(a, b). The NetBSD cstring properties come from the kernel, not the user. The test for units did a prefix match, but that looked like a bug, the unit is "Watt hour" in my Virtual box.
2016-08-14Remove warnings about unused variables in slurp_battery_info on OpenBSD.Tommie Gannert
2016-08-03Move OS-specific code to slurp_battery_info.Tommie Gannert
2016-08-03Introduce a struct battery_info to carry information from data retrieval to ↵Tommie Gannert
the output formatter.
2016-08-03Refactor common seconds_remaining code in print_battery_info.Tommie Gannert
2016-08-03Remove an END_COLOR in print_battery_info for OpenBSD.Tommie Gannert
This was probably a bug since it makes no sense to have here.
2016-08-03Move START_COLOR to after OS-specific code.Tommie Gannert
This uses the more direct tests of whether percentage_remaining and seconds_remaining are available or not (rather than looking at present_rate).
2016-08-03Remove consumptionbuf from print_battery_info.Tommie Gannert
2016-08-03Remove emptytimebuf from print_battery_info.Tommie Gannert
This changes the behavior for NetBSD: previously this time was not shown while charging. On Linux it was treated as "full time". This change makes all OSes behave the same. OpenBSD and FreeBSD did not support emptytime previously.
2016-08-03Remove remainingbuf from print_battery_info.Tommie Gannert
2016-08-01Remove percentagebuf from print_battery_info.Tommie Gannert
2016-08-01Remove statusbuf from print_battery_info.Tommie Gannert
2016-03-21Added status_unk to battery_infoeoin
2016-01-25This removes the 'remaining' time when the battery is full, since the ↵Clayton Craft
remaining time is always 00:00:00. When the battery is discharging, the remaining time will show up again if the user has set their format correctly.
2015-10-08Properly detect the battery charging status under FreeBSD.John Baldwin
The hw.acpi.battery.state sysctl returns a bitmask of flags as defined in <dev/acpica/acpiio.h>. Use constants from this header to examine the state and check for the charging flag to determine if the battery is charging.
2015-10-04Added support for lemonbarBrendan Van Hook
2015-05-20Clamp the percentage at 100% when last_full_capacity is enabled.Michael Stapelberg
2015-05-05Changed battery info output to HH:MM for consistency accross all platformsNicholas Helke
2015-03-16clang-format-3.5 -i **/*.[ch], update modelineMichael Stapelberg
From here on, we’ll use clang-format to automatically format the source. This has worked well in i3, so we are introducing it for i3status.
2014-12-22Avoid use of uninitialized variable in print_battery_infoAlexander Monakov
The boolean flag 'watt_as_unit' may be used without being initialized if the configured battery path does not contain expected statistics (for example if it is misconfigured and points to AC adapter info or simply an unrelated file). Even though it does not cause ill effects, it causes a warning (true positive) when running i3status under Valgrind. Initialize the variable to make code well-defined.
2014-10-07Created three individual Strings for each battery status (charging, ↵Cyril Andreatta
dicharching, full) Replaced hard coded status strings (CHR, BAT, FULL) in print_battery_info.c with user defined strings. The new strings are 'status_chr', 'status_bat' and 'status_full' and can be set in i3status.conf. e.g. status_chr = "⚡ CHR" If any of the new status strings is omitted the standard strings (CHR, BAT, FULL) are used.
2014-08-25Fix battery indicator on systems without POWER_SUPPLY_VOLTAGE_NOW.Klemen Košir
In my case, the voltage variable would stay initialized as -1, which caused the calculation of battery charge percentage to be incorrect (I would get the message that there is no battery present or even -0% charge). I have no idea how this would affect other systems, since I don't have a chance to test this.
2014-05-31Use the absolute values for (dis)charging ratesMichael Stapelberg
Apparently some notebooks report a negative current, whereas most don’t. fixes #1249
2014-04-30Implement battery functionality for NetBSD usersAlexander Vasarab
This patch takes a similar approach as the NetBSD CPU temperature code in that it uses proplib(3) to walk dictionaries supplied by envsys(4). In addition to providing the basic functionality, it: * Provides all existing format specifiers (%emptytime %consumption %status %percentage %remaining) * Respects all existing config options (hide_seconds, low_threshold, integer_battery_capacity, last_full_capacity) * Projects "time until full" when battery status is CS_CHARGING
2014-03-12Unify use of string comparisonsMats
* strncmp(s1, s2, strlen(s2)) → BEGINS_WITH(s1, s2) * strncmp(s1, s2, strlen(s1)) → strcmp(s1, s2) * Prefer case-insensitive comparison for options
2014-03-12For the %percentage display of batteries, drop the leading '0' for values < 10.Jasper Lievisse Adriaanse
2014-02-08Add hide_seconds optionIakov Davydov
fixes: #1134
2013-05-04fix #1017: i3status uses generic battery instanceJonas Cleve
2013-03-19Enable colored output for battery on FreeBSDBaptiste Daroussin
2013-03-09Added format_down option for battery if no battery is available.Christoph Göttschkes
2013-02-23battery: initialize colorful_output to falseMichael Stapelberg
2013-02-14Added option to show battery capacity without decimalsJulien Lequertier
2012-11-15DragonFlyBSD support addedScott Tincman
2012-10-16bugfix: colorize output even without discharge rate (thanks f8l)Simon Elsbrock
On some systems, the discharge rate may be missing, although the battery is still working. This leads to an edge case on Linux systems in which the output may not be colorized although a threshold was defined. This commit fixes the behavior by colorizing output if threshold_type is set to "percentage". Since we cannot calculate remaining time without discharge rate, output is still uncolorized in case of threshold_type set to "time".
2012-10-10Various fixes for the OpenBSD section of the battery backend.Jasper Lievisse Adriaanse
- fix the battery status printing in %status. - fix remaining time when we're charging. - use colors to indicate battery status. - small cleanups.
2012-09-05print_battery.c: do END_COLOR only if START_COLOR was usedSimon Elsbrock
2012-08-31Eat unnecessary space from the battery format str.Piotr Domagalski
If the battery is not discharging it may be not possible to give information on remaining time or consumption. The resulting strings (%remaining, %consumption, %emptytime) are empty then. But because they are in the format string, the output string contains unnecessary spaces in this case. This commit makes i3status strip these spaces.